Very Low Cost Underground System Using Traditional Water Well Drilling
- Key words
- Geo-heat pump system, low cost heat extraction, traditional well drilling, combination piping of horizontal and shallow well, geothermal direct use
- Conference
- Asian Geothermal Symposium
- Year
- 2004
- Session
- Direct Use and Methodology
- Language
- English
Full text
151 KB, opens in a new tab
Abstract
Combination piping of horizontal and shallow well has enough power for air condition of small house. All such construction is done by civil engineering machine and traditional well drilling. Experimental data of Ogatamura shows that the heat extractions are 2.5kw (23W/m) at heating and 4.8kW (44W/m) at cooling. We proposed 3 types of heat extraction systems. One is shallow well using underground water. Second is closed piping system of 1m horizontal trench and 4m wells. Third is combination of one and two but not use underground water. Relatively deep (8-16m) well start to drill bottom of 4m well of second case. This well is used for coaxial water circulation system. All of them are very low cost (up to 200,000yen) and easy to construct. We call these system as “Akita Model” and try to penetrate the market with local small company.
Copyright 2004, Asian Geothermal Symposium. Readers who download papers from this site should honour the copyright of the original authors, and may not copy or distribute the work further without the permission of the original publisher.