Conference Papers Database New search

Kawerau Steamfield Design

Michael Rock

Key words
Steamfield conceptual design, RPF, SAGS, pipe size optimization
Location
Kawerau, New Zealand; Taupo Volcanic Zone
Conference
World Geothermal Congress
Year
2010
Session
25. Production Engineering and Steam Gathering Systems
Language
English
Paper number
2513

Full text

471KB, opens in a new tab

Abstract

The steamfield production piping size for the Kawerau geothermal power plant was determined by using predicted well performance and decline rates.
The final steamfield configuration used six production wells. The design optimization was based on the test data from four wells, which was extrapolated to include both “normal” and “big bore” wells.
A method of using the predicted well performance to determine the influence on steamfield piping size is reviewed. The method takes into account capital cost and make-up well drilling, and how this impacts net present value.