Conference Papers Database New search

Analysis of Pressure Transient Response for an Injector under Hydraulic Stimulation at the Salak Geothermal Field, Indonesia

Jorge A. Acuna

Key words
Fall off, fractional flow, fractal flow, stimulation, Salak, Awibengkok
Location
Awibengkok, Indonesia; Java
Conference
World Geothermal Congress
Year
2010
Session
22. Reservoir Engineering
Language
English
Paper number
2276

Full text

1113KB, opens in a new tab

Abstract

Four pressure fall-off pressure transient tests were conducted in a well being stimulated by high pressure injection. The tests were analyzed with a technique based on fractional flow in a composite reservoir. The results show the progress of the stimulation process as the measured reservoir properties change from test to test. Novel techniques for analysis of pressure transient tests are demonstrated. The reason for the very large wellbore storage effect usually found in injection fall-off tests is discussed and considered in the analysis.

Copyright 2010, International Geothermal Association. Readers who download papers from this site should honour the copyright of the original authors, and may not copy or distribute the work further without the permission of the original publisher.

Attend the 2029 World Geothermal Congress. Congress details
You have opened 0 records today from 216.73.216.139 (216.73.216.139).
Viewed 26 September 2026, 10:39 am.