Conference Papers Database New search

THE REINJECTION TESTS IN BASEMENT GEOTHERMAL RESERVOIR, TIANJIN, CHINA

Wang Kun, Li Chunhua

Key words
reinjection test, basement, geothermal reservoir
Conference
Beijing International Geothermal Symposium
Year
2002
Session
Research and Application of Techniques
Language
English

Full text

sale only, opens in a new tab

Abstract

By the end of 2000, there are about 184 production wells (including 12 reinjection well) in Tianjin. The annual production rate is 12Mm3 and the reinjection rate is 1.6612Mm3. The water level is between -22 to -70m, the annual draw-down rate is 6-9m. The reinjection test in WR45 doublet system is analyzed here, but we have not observed any temperature changes in surrounding production geothermal wells up to present. The main side effect anticipated from reinjection is the cooling of the reservoir. Tracer test is very important for understanding the transport way and transport channel/space in doublet production/reinjection system, and estimating the possible cooling resulting from the injection.

Copyright 2002, Geological Publishing House, Beijing. Readers who download papers from this site should honour the copyright of the original authors, and may not copy or distribute the work further without the permission of the original publisher.