Title:

Man-made, low-temperature geothermal reservoirs in abandoned workings of underground mines on example of Nowa Ruda coal mine, Poland

Authors:

Zbigniew Malolepszy

Key Words:

geothermal reservoir, coalmine, modelling.

Geo Location:

Nowa Ruda, Poland

Conference:

Iceland Geothermal Conference

Year:

2003

Session:

Drilling and Production

Language:

English

File Size:

148K

View File:

Abstract:

The flooded, abandoned underground mines form low-temperature geothermal reservoirs, are characterized by the site-specific geological, hydrogeological, and technical conditions of mining fields. The large volumeof underground open spaces with high permeabilities that are left after mining activity, in areas with relatively high geothermal gradients, may be considered as man-made reservoirs of warm mine waters.In the process of adaptation of mine workings for reservoir purposes, the subsidence of the mining area should be considered, which reduces the volume of water-filled spaces in the mine, and also the high amount of total dissolved solids (TDS) and gas in mine waters. The rate of cooling of the rock mass during mining activity and the time for thermal recovery to natural, undisturbed thermal conditions are also important. The former coal mine of Nowa Ruda in southwestern Poland is presented as an example. In the Piast mining field, the abandoned and flooded workings in the Carboniferous Lower Zacler beds contain about 5,000,000 cubic meters of water at a temperature of 16-26?C. The exploitation of the mine water for geothermal heat pumps is planned. Two two-dimensional (2-D) numerical models based on the TOUGH2 program have been developed to introduce heat exchange modeling into this mining field. The model of temperature recovery of abandoned workings shows the time required to return to natural thermal conditions in a rock massif that has cooled down during coal mining. The expected time for temperature recovery is approximately 10 years. The model of a geothermal doublet producing water at a temperature of 23 ?C from abandoned workings presents the rate of cooling of the reservoir at production rates of 10 l/s (thermal outputpower ~800 kWth) and 20 l/s (thermal output power ~1600 kWth).


ec2-18-224-61-19.us-east-2.compute.amazonaws.com, you have accessed 0 records today.

Press the Back button in your browser, or search again.

Copyright 2003, Geothermal Association of Iceland: Readers who download papers from this site should honor the copyright of the original authors and may not copy or distribute the work further without the permission of the original publisher.

Accessed by: ec2-18-224-61-19.us-east-2.compute.amazonaws.com (18.224.61.19)
Accessed: Monday 20th of May 2024 07:44:36 PM