Conference Papers Database New search

In-Situ Thermal Response Testing ? New Developments

Nina Mattsson, Gilbert Steinmann and Lyesse Laloui

Key words
Thermal Response Testing, Geothermal Energy, In-Situ Testing, Line Source, Ground Coupled Heat Pump
Conference
European Geothermal Conference
Year
2007
Session
Shallow Geothermal Energy
Language
English
Paper number
193

Full text

270KB, opens in a new tab

Abstract

The number of installations of ground source heat pump (GHSP) systems is rapidly growing in Switzerland. For any installation it is critical to have a correct estimation of the ground thermal properties to ensure optimal energy savings and for larger developments the in-situ thermal response test (TRT) provides a cost-effective method to achieve this. The authors have developed a compact mobile test device for the TRT, where all the required components are held in a suitcase-sized container. The compact module has been equipped with a modem to facilitate remote data-monitoring. This addition has enabled the engineer to overview the results in real time and to switch the heater on and off via a mobile phone, something that has reduced the time spent on site and therefore also the cost. The new compact test device has been used to determine the thermal conductivity for several larger GHSP systems in Switzerland and France and have shown equivalent results to previous trailer-sized equipments. The development and operation of the device is described together with a case study of a performed in-situ thermal response test.

Copyright 2007, Geothermische Vereinigung e.V. - Bundesverband Geothermie. Readers who download papers from this site should honour the copyright of the original authors, and may not copy or distribute the work further without the permission of the original publisher.

You have opened 0 records today from 216.73.216.227 (216.73.216.227).
Viewed 23 September 2026, 4:33 pm.