Unterhaching Geothermal Well Doublet: Structural and Hydrodynamic Reservoir Characteristic; Bavaria (Germany)
- Key words
- Electricity generation, Molasse basin, test data, temperature
- Location
- Unterhaching, Germany
- Conference
- European Geothermal Conference
- Year
- 2007
- Session
- Geothermal Energy Use in Munich Area
- Language
- English
- Paper number
- 047
Full text
449KB, opens in a new tab
Abstract
At Unterhaching, two wells ? Gt Uha1a for production, Gt Uha2 for injection ? were drilled and tested for the cogeneration of electricity and heat. Very high productivities of both could be determined. These good inflows are attributed to the influence of fault systems. In particular, the well Gt Uha2 was drilled through a fault with a vertical throw of 238 m. At the top of the aquifer, the temperature of the produced water was 123 ?C (Gt Uha1a) or approx. 134 ?C (Gt Uha 2). The high temperatures in the Gt Uha2 well are ascribed to waters circulating in a deepreaching fault system. Inflows within the Malm come exclusively from the Upper Malm (Malm Zeta).
Copyright 2007, Geothermische Vereinigung e.V. - Bundesverband Geothermie. Readers who download papers from this site should honour the copyright of the original authors, and may not copy or distribute the work further without the permission of the original publisher.