Conference Papers Database New search

A Borehole Simulation Autoclave for Logging Tool Testing at HDR Environment

Paul Hegemann and Fritz Rummel

Key words
boreholes, autoclave, logging tool testing, HDR
Conference
World Geothermal Congress
Year
1995
Session
SECTION 12 - Advanced Technologies (HDR - Magma - Geopressur
Language
English
Paper number
4-Hegemann

Full text

Opens in a new tab

Abstract

A high-pressure high temperature autoclave system was developed to permit testing of newly designed logging tools under hostile HDR geothermal environmental conditions. autoclave has the following specifications: - inside diameter: - inside length: - max. operating pressure: - max .temperature: - pressure medium: fluids 165mm 7800 (307") 150 (21750 psi) 200 (392 Pressure and temperature can be held constant within 1 per cent of their maximum values. The autoclave has an inside mounted 7-conductor cablehead and electrical as well as hydraulic inlets outlets at various positions to allow tool operation of almost any kind during testing.

Copyright 1995, International Geothermal Association. Readers who download papers from this site should honour the copyright of the original authors, and may not copy or distribute the work further without the permission of the original publisher.