H2S Abatement in the Cold Gas Cap of Geothermal Wells Before Kick-Off Tests
- Key words
- geothermal, geochemical, H2S abatement, environmental control, well, well performance tests
- Conference
- World Geothermal Congress
- Year
- 2000
- Session
- Environmental and Social Aspects
- Language
- English
- Paper number
- R0738
Full text
946, opens in a new tab
Abstract
A new system for in-well H2S abatement before kick-off tests has been developed. In this process, the H2S present in the cold gas cap in the upper portion of the well is removed by treating the gas with a hydrogen peroxide solution at neutral pH. The reactant is continuously pumped with a special injection head descending along the well. Results of a field experiment are reported showing the reliability of the process. ENEL has adopted the reported technology and is currently using this method in the treatment of shallow cold gas cap before well kick-off tests whenever an atmospheric gas discharge is necessary for the well performance test.
Copyright 2000, International Geothermal Association. Readers who download papers from this site should honour the copyright of the original authors, and may not copy or distribute the work further without the permission of the original publisher.