Conference Papers Database New search

Thermal Calculations of Geothermal Heat Utilising One-Well Systems with Injection and Production

Tomasz Kujawa and Wladyslaw Nowak

Key words
geothermal heat exchanger, field temperature, injection and production well, Field exchanger, borehole
Conference
World Geothermal Congress
Year
2000
Session
Direct Use, Geothermal Heat Pumps
Language
English
Paper number
R0682

Full text

430, opens in a new tab

Abstract

A method of heat calculation and an analysis of the influence of the annular injected fluid on the inner-liner produced fluid for two kinds of heat exchangers in a one-well system is presented. The exchangers are partly immersed in a geothermal reservoir from which the heat of the geothermal water is drawn. The first part of the heat exchanger is located in the impervious caprock where temperature changes linearly. Graphs of changes of fluid temperature for various production and reservoir conditions are also presented.

Copyright 2000, International Geothermal Association. Readers who download papers from this site should honour the copyright of the original authors, and may not copy or distribute the work further without the permission of the original publisher.

Attend the 2029 World Geothermal Congress. Congress details
You have opened 0 records today from 216.73.216.227 (216.73.216.227).
Viewed 23 September 2026, 1:04 am.