Exergy Analysis of the Mindanao 1 & 2 Geothermal Power Plants
- Conference
- PNOC-EDC Geothermal Conference
- Year
- 2002
- Session
- Reservoir Engineering/ Geophysics/ Geology/ Power Plant
- Language
- English
Full text
457KB, opens in a new tab
Abstract
An exergy analysis was made on Mindanao 7 & 2 Geothermal Plants, both based on the MHI tuhine and flash system. A program was used to simulate actual plant operation to calculate exergy, identify exeqy losses and estimate the efficiencies of both plants. A comparative analysis of both plants was made using the same reference environment and their actual operating environment. The exergy analysis shows that at their actual operating environment, M7GP has 8 net plant second law efficiency of 60.4 % while M2GP has 57.2 %. At the same refemnce environment, the efficiency of M7GP dropped to 56.3 %. The analysis showed that the cooling water system, particulariy the condenser and cooling tower and the tuhines need further investigations to improve exegetic eft"rciency. The extraction and utilization of low-pressue steam from M7GP to generate additbnal power for M2G P maximizes the efficient utilization of the available geothermal msoune and resulted to an increase in net plant second law efficiency of 63.32 %. Since exergy analysis expmsses the relationship between the system and the environment, it should be integmted in the design of engineering systems and in life cycle analysis of geothermal systems.
Copyright 2002, PNOC-EDC. Readers who download papers from this site should honour the copyright of the original authors, and may not copy or distribute the work further without the permission of the original publisher.