Conference Papers Database New search

LWD Acquisition of Caliper and Drilling Mechanics as a New Approach on Geothermal Drilling Operation, A Case Study in Sorik Marapi Field – Indonesia

V.B. Manurung, L. Warkhaida, D. Hutabarat, N. Sirait, S. Wisnuwardhana, C. Simatupang, D. Sanjaya, Ashadi, R. Pasikki, R.B. Putra, K. Yustendi

Key words
Geothermal Drilling; Geothermal Formation, Geothermal Technologies, LWD, Vibration, Caliper, Case Study
Conference
New Zealand Geothermal Workshop
Year
2022
Session
Session 7.3 - DRILLING and WELL TESTING
Language
English
Paper number
4

Full text

3905KB, opens in a new tab

Abstract

The geothermal drilling environment presents many obstacles that limit the use of directional-drilling and logging-whiledrilling (LWD) technologies, such as borehole washout, mud losses, severe vibration, and high temperature. The case study presented in this paper demonstrates a novel practice to enhance data logging in geothermal drilling by deploying advanced telemetry and LWD technologies. This operation aims for continuous improvement in geothermal drilling operations.
The case study covers the 12.25-in. hole section of well XXE-05 in the Sorik Marapi Geothermal Field. The LWD string consisted of electromagnetic (EM) telemetry, pressure while drilling (PWD), vibration (DDSr), and acoustic calliper (ACAL). Through this tool configuration, the operator acquired drilling mechanics and calliper logs in real-time and recorded mode, enabling effective monitoring and evaluation of wellbore stability.
Throughout the real-time acquisition, EM telemetry provided a data rate to the surface unit three times faster than conventional tools. Furthermore, with the integration of calliper and drilling mechanics data (vibration and equivalent circulating density), the borehole conditions became more visible to the directional driller, allowing better control of drilling parameters to minimize vibration and achieve
optimum hole cleaning in washed-out or tight formation sequences. The recorded data from the calliper sensor indicated an average of 8.6% washout for the entire 12.25-in. interval. Washout intervals were compared with loss occurrence during drilling and the presence of smectite-bearing paleosols, showing that the washout zones associate with the latter, supporting the smectite-bearing paleosol model in explaining the cause of stuck pipe incidents in the Sorik Marapi field. In addition, measurements of hole ovality were compared with the interpreted fault trend, providing further insight into the existing model. In general, this LWD case study has given added value through geothermal borehole characterization, from drilling hazard identification to subsurface analysis.
Identified challenges while running LWD in this geothermal environment were addressed for future improvements, such as the effect of tool eccentricity and the impact of vibration. Perusal of both real-time and recorded calliper and drillingmechanics data has opened various possibilities for maximizing the sensor usage in future wells.

Copyright 2022, University of Auckland. Readers who download papers from this site should honour the copyright of the original authors, and may not copy or distribute the work further without the permission of the original publisher.

You have opened 0 records today from 216.73.216.152 (216.73.216.152).
Viewed 23 September 2026, 10:30 pm.