Conference Papers Database New search

Testing of cyclone separators and steam pipelines for separation and scrubbing performance

T. Misa, E. Mroczek

Key words
steam separation, two phase flow, pipeline scrubbing, steam sampling, tracer testing, steam cleanliness, steam purity, steam quality
Conference
New Zealand Geothermal Workshop
Year
2017
Session
Session 5.1: Production
Language
English
Paper number
71

Full text

866KB, opens in a new tab

Abstract

Testing for separation and scrubbing performance was undertaken on Intermediate Pressure (IP) and Low Pressure (LP) steam systems of a geothermal steamfield and power station. Testing was completed at a number of process conditions to determine what operating conditions caused changes in separation and scrubbing performance.
A suite of steam and separated water flow measurements were used in conjunction with changes in natural sodium and injected fluorescein carryover to observe the effect on plant performance. Results showed an unexpected significant holdup time of the added tracer, separator performance below design and the effects of flow regimes and geometries on system performance. Difficulties and benefits of completing this type of testing on operational industrial plant are discussed.

Copyright 2017, University of Auckland. Readers who download papers from this site should honour the copyright of the original authors, and may not copy or distribute the work further without the permission of the original publisher.