The Estimation of the Material Corrosion Based on Previous Data and Compare with On-Site Test at Geothermal Field.

N. Yanagisawa,Y. Masuda, K. Osato, M. Sato, K. Kasai, K. Sakura, T. Fukui

Key words
corrosion rate, carbon steel, Kakkonda geothermal field, Cr equivalent, pH, temperature
Conference
New Zealand Geothermal Workshop
Year
2016
Session
5.5
Language
English
Paper number
32

Full text

421KB, opens in a new tab

Abstract

The material selection of pipeline and well in geothermal plant is important for risk management to prevent scale and corrosion problem. Especially, in acidic condition with high temperature region, the material corrosion problem becomes more serious.
To solve this problem, we started the project of the Development of Geothermal Power Plant Risk Assessment System supported by NEDO from 2014. In this project, based on the data collected from 1974 to 2002 at AIST, we made calculation system to estimate the corrosion rate from pH, temperature and material component.
And we try to compare the calcurated data with the on-site corrosion test at Kakkonda geothermal field at FY2015. The corrosion rate of carbon steel at Kakkonda is about 1.6mm/year at on-site examination under pH 3.6 and 145 ÂșC and match to the result of calculation based on previous data-base. On the other hand, TN80Cr13 and TN110Cr13S, the calculated corrosion rate is higher than the on-site corrosion rate.

Copyright 2016, University of Auckland. Readers who download papers from this site should honour the copyright of the original authors, and may not copy or distribute the work further without the permission of the original publisher.