Ultrasonic equipment aimed to detect grouting homogeneityin geothermal heat exchangers

Colombero, C; Comina, C; Giuliani, A; Mandrone G

Key words
heat exchangers, geothermal grouting, quality test, ultrasonic waves
Conference
European Geothermal Congress
Year
2016
Session
Technology and Best practice – Heat Pumps
Language
English
Paper number
T-HP-336

Full text

1320KB, opens in a new tab

Abstract

The purpose of this study is to assess homogeneity and integrity of cementing grout in vertical borehole heat exchangers used for geothermal heat pumps using an ultrasonic non-destructive test. The used testing equipment, TUC (Ultrasonic Test to certificate grouting Continuity), is based on an ultrasonic system able to generate and record wave propagation from the inside of heat exchangers to the surrounding (cementation and soil, possibly). Differences in signal characteristics of the recorded waves along the pipe can indirectly provide useful information to evaluate the successful realization of the well cementation in terms of vertical homogeneity and continuity. Both laboratory and field tests have been evaluated and are hereafter presented to verify tests effectiveness and discuss eventual limitation of the proposed approach.