Ultrasonic equipment aimed to detect grouting homogeneityin geothermal heat exchangers
- Key words
- heat exchangers, geothermal grouting, quality test, ultrasonic waves
- Conference
- European Geothermal Congress
- Year
- 2016
- Session
- Technology and Best practice – Heat Pumps
- Language
- English
- Paper number
- T-HP-336
Full text
1320KB, opens in a new tab
Abstract
The purpose of this study is to assess homogeneity and integrity of cementing grout in vertical borehole heat exchangers used for geothermal heat pumps using an ultrasonic non-destructive test. The used testing equipment, TUC (Ultrasonic Test to certificate grouting Continuity), is based on an ultrasonic system able to generate and record wave propagation from the inside of heat exchangers to the surrounding (cementation and soil, possibly). Differences in signal characteristics of the recorded waves along the pipe can indirectly provide useful information to evaluate the successful realization of the well cementation in terms of vertical homogeneity and continuity. Both laboratory and field tests have been evaluated and are hereafter presented to verify tests effectiveness and discuss eventual limitation of the proposed approach.
Copyright 2016, EGEC / EGC2016. Readers who download papers from this site should honour the copyright of the original authors, and may not copy or distribute the work further without the permission of the original publisher.