Conference Papers Database New search

Customized Well Test Methods for a Non-Customary Geothermal Well

M. Burr

Location
The Geysers, California
Conference
Stanford Geothermal Workshop
Year
1986
Session
Well Testing
Language
English

Full text

390KB, opens in a new tab

Abstract

Recent testing of Thermal 4, The Geysers blowout well, has shown that the flow has two different components: a low enthalpy, mineral-laden flow from a well drilled within the existing wellhead and a high flowrate, high enthalpy annular flow. The commingled flows were mechanically separated and individually tested. The results of the test show that the flows are from two very different sources that are in weak hydraulic communication. Work is in progress to apply this information to bring Thermal 4 within compliance of the 1986 air quality regulations.

Copyright 1986, Stanford Geothermal Program. Readers who download papers from this site should honour the copyright of the original authors, and may not copy or distribute the work further without the permission of the original publisher.

Attend the next Stanford Geothermal Workshop. Workshop details
You have opened 0 records today from 216.73.217.2 (216.73.217.2).
Viewed 21 September 2026, 1:34 am.