MEASUREMENT OF TWO PHASE FLOWS IN GEOTHERMAL PIPELINES USING RADIO FREQUENCY (RF) POWER MEASUREMENTS: EXPERIMENTAL RESULTS
- Key words
- Geothermal flow measurement, Well discharge testing, two-phase, Horizontal Discharge, Enthalpy, dryness fraction, Orifice Plate
- Conference
- New Zealand Geothermal Workshop
- Year
- 2015
- Session
- Session 2B: Above Ground
- Language
- English
- Paper number
- 41
Full text
784.92 KB, opens in a new tab
Abstract
A sensor scheme using radio frequency (RF) power has been investigated for the measurement of two phase flow in geothermal pipelines. The method can provide continual monitoring and be installed into piping in areas of limited pipe runs. The measurement is used to calculate dryness fraction, void fraction, and possibly flow rate in the pipe, and should be independent of temperature. It is accomplished by measurement of RF energy transmitted into the contents of the pipe by antenna, and received by a separate receive antenna. Tests were performed to determine feasibility, investigate antenna designs, and improve transmitter protection schemes. The results and analysis presented in this work show the method has the potential to measure two-phase flow in geothermal pipelines and wells with at least 2% accuracy. It may be used to complement (improve) the accuracy of existing two-phase orifice plates currently in use in geothermal pipelines, or may be used stand-alone, for the measurement of total mass flow rate and enthalpy in geothermal or other pipelines and wells on a continuous basis.
Copyright 2015, University of Auckland. Readers who download papers from this site should honour the copyright of the original authors, and may not copy or distribute the work further without the permission of the original publisher.