Reverse Foam Latex Cementing 11? Inch Intermediate Casing in PGV Well KS-15

Peters, Brad;Samuel, Abraham S.; Rickard, William M.; Sauter, Mark

Key words
Geothermal; reverse cementing; foam; latex; nitrogen; lost circulation; equivalent circulating density; design; Hawaii; Puna; rift zone; volcano; inner-string
Location
Puna, Hawaii
Conference
Geothermal Resources Council Transactions
Year
2013
Session
Cementing; Lost circulation
Language
English

Full text

Open the paper

Opens in a new tab

Abstract

Many challenges arise when cementing geothermal wells. Lost circulation and temperature are the main culprits for increased cost when trying to achieve zonal isolation. At the Puna geothermal field, extreme lost circulation and bottom hole static temperatures in excess of 500°F are not uncommon. The extreme conditions, coupled with the remoteness to drilling service providers, represent a significant challenge. Reverse cementing was used to successfully complete a job in a challenging environment and also significantly reduce cost in the cementing phase of well completion. A demonstration of proper planning, designing, and execution of the job is presented.

Copyright 2013, Geothermal Resources Council. Readers who download papers from this site should honour the copyright of the original authors, and may not copy or distribute the work further without the permission of the original publisher.