Stibnite Scaling in a Binary Power Plant in Turkey
- Key words
- stibnite, scaling, binary plant, Turkey
- Conference
- World Geothermal Congress
- Year
- 2015
- Session
- Corrosion and Scaling
- Language
- English
- Paper number
- 27040
Full text
1427 KB, opens in a new tab
Abstract
A geothermal binary cycle power plant in Germencik Turkey has shown a serious decrease in performance at the beginning of summer 2013. Increase in the differential pressure of the power planted suggested that clogging was present in the system. All heat exchanger units were opened and a black-greyish scale with a thickness varying between 1 to 4 mm was encountered in all heat exchangers. Deposits were analyzed and the results showed that they consist of %60-70 antimony and %30-40 sulfide, which led to the conclusion that stibnite was the main cause of scaling in the system. This was the first recorded stibnite scaling phenomenon in Turkey. Stibnite scaling occuring conditions, preventation and cleaning studies have been discussed in this paper.
Copyright 2015, International Geothermal Association. Readers who download papers from this site should honour the copyright of the original authors, and may not copy or distribute the work further without the permission of the original publisher.