Well Remedial Evaluation and Prediction of Post Remedial Condition of a Suspected Multiple Feedzone Well Using Wellbore Simulation, Case Study: Well Sendangan-4
- Key words
- casing break, well remedial, wellbore modelling, Tompaso
- Conference
- World Geothermal Congress
- Year
- 2015
- Session
- Reservoir Engineering
- Language
- English
- Paper number
- 22050
Full text
988 KB, opens in a new tab
Abstract
Sendangan-4 was a development well of Tompaso Geothermal Prospect located in Minahasa, North Sulawesi. The well had a big-hole configuration with 13-3/8” production casing. Early production test resulted in mass flow of ± 500 ton/hr production with flowing enthalpy of ± 950 kJ/kg. After production test, reservoir temperature dropped from 260°C to 70°C causing well failed to discharge. Downhole well survey indicated that casing break occurred. This study analyzed well data including the possibility of well remedial and prediction of well performance after remedial based on wellbore simulation model.
Copyright 2015, International Geothermal Association. Readers who download papers from this site should honour the copyright of the original authors, and may not copy or distribute the work further without the permission of the original publisher.