Use the Software Wellsim® to Determine the Causes of the Decline in Production H-1D Well After Mechanical and Chemical Cleaning of the Los Humeros (Mexico) Geothermal Field
- Key words
- Humeros Geothermal Field, H-1D wel, lsimulation, Wellsim®.
- Conference
- World Geothermal Congress
- Year
- 2015
- Session
- Reservoir Engineering
- Language
- English
- Paper number
- 22021
Full text
837 KB, opens in a new tab
Abstract
Due to the decline in production from H-1D well on the Los Humeros Geothermal Field (HGF) caused by the deposition of calcite and silica inside of the pipes and the annular area between the slotted liner and hole 8,5”, it was subject to mechanical and chemical cleaning between June and July 2010. The results were successful and the increase in production was 766%. However, the well production drop drastically in the evaluation stage to a similar production measured before acid stimulation. To understand the phenomenon occurred in the well, analysis of the chemical and thermodynamic information of the fluid saturation indices, go devils was performed. Additionally the mechanisms of production into the well were analyzed; comparing the data obtained with the simulated data scenarios before the stimulation job using the simulation software Wellsim®. In this paper, the analysis of causes of the decline production in H-1D Well in the Los Humeros Geothermal Field is presented.
Copyright 2015, International Geothermal Association. Readers who download papers from this site should honour the copyright of the original authors, and may not copy or distribute the work further without the permission of the original publisher.