Conference Papers Database New search

The Process Design of Steamfield Pipeline Systems for Transient Operation from Liquid Dominated Reservoirs

Watson A., Brodie A. J. and Lory P. J.

Conference
New Zealand Geothermal Workshop
Year
1996
Session
Engineering
Language
English

Full text

204KB, opens in a new tab

Abstract

Geothermal plant designed for base load operation nevertheless experiences transients that need to be designed for. The water flowing from separators to reinjection wells is at saturation temperature, and is liable to boil. This feature is the most significant in transient considerations. Bubble growth in the reinjection lines may cause separator flooding and turbine damage. Bubble collapse may cause pipe and valve failure. The paper derives a simple allowable rate of change of separator pressure to avoid reinjection line boiling. The paper describes a general approach and a simplified method of calculating the separator pressure transients for any design, for comparison with the allowable rates.

Copyright 1996, University of Auckland. Readers who download papers from this site should honour the copyright of the original authors, and may not copy or distribute the work further without the permission of the original publisher.

You have opened 0 records today from 216.73.216.139 (216.73.216.139).
Viewed 25 September 2026, 6:13 pm.