Pilot Testing of a Novel Hydrogen Sulfide Abatement Process - Mak-Ban Unit 3, Bulalo, Philippines, Geothermal Field.
- Location
- Bulalo/Mak-Ban, Philippines; Luzon
- Conference
- New Zealand Geothermal Workshop
- Year
- 1992
- Session
- Environment
- Language
- English
Full text
328KB, opens in a new tab
Abstract
Anew liquid phase oxidation process for abatement of hydrogen sulfide emissions from geothermal power plants was tested in 1991 at Mak-Ban Unit 3, Bulalo, Philippines geothermal field. The process comprises contacting neutralized cooling tower circulating water with a small, substantially less-than-stoichiometric amount of an oxidizing biocide required to oxidize sulfide to sulfate. Determining precise abatement efficiencies in the Unit 3 direct contact condenser proved extremely difficult. Process monitoring suggested that the oxidation reaction in the direct contact condenser resulted in up to 50 - 77% abatement of emissions from both the vent gas ejectors and degassing at the cooling tower. Microbiological growth in the circulating water was controlled by periodically adding a second (non-oxidizing) biocide. The oxidizing biocide treatment had little, if any, effect on circulating water corrosivity.
Copyright 1992, University of Auckland. Readers who download papers from this site should honour the copyright of the original authors, and may not copy or distribute the work further without the permission of the original publisher.