Conference Papers Database New search

Vertically-Upward Two-Phase Flow in an Annulus

Torrens T.S. and Lee, K.C.

Conference
New Zealand Geothermal Workshop
Year
1994
Language
English

Full text

456KB, opens in a new tab

Abstract

This describes an experimental study of pressure drop in vertically two phase flow in annulus. An experimental rig was designed and built to pressure drop and observe flow regime for air mixtures in a vertical 48.3 x 74.0 annulus. Measured pressure drop is compared to that predicted by the of Duns Ros Hagedorn Brown Orkiszewski Aziz et al. (1972). Beggs Brill (1973) and Caetano et al. These correlations are also applied to the experimental results of Gaither et al. (1963) who measured pressure drop for water gas mixtures through a 1"x 2" (25 x 50 annulus inside a ft (305m) deep test well.

Copyright 1994, University of Auckland. Readers who download papers from this site should honour the copyright of the original authors, and may not copy or distribute the work further without the permission of the original publisher.

You have opened 0 records today from 216.73.217.5 (216.73.217.5).
Viewed 22 September 2026, 1:15 am.