Conference Papers Database New search

Detecting Diffuse CO2 Emissions Along The Ngapouri Fault Using A Turnable Diode Laser

Mazot, Agnes ., Rae, Andrew . and Jentsch, Anna

Key words
Tunable Diode Laser, geothermal CO2 mixing ratio measurements, Ngapouri Fault, Waiotapu-Waikite geothermal system
Location
Waiotapu-Waikite, New Zealand
Conference
New Zealand Geothermal Workshop
Year
2014
Session
Geothermal Geochemistry
Language
English
Paper number
28

Full text

454 KB, opens in a new tab

Abstract

CO2 mixing ratio measurements have been performed for the first time on the margins of Waiotapu geothermal area using an open-path Tunable Diode Laser (TDL). The survey measurements were conducted along strands of the Ngapouri Fault that extend to the south-southwest away from Waiotapu. The main purpose of these surveys was to test whether geothermal CO2 mixing ratios can be detected along Ngapouri Fault strands where geothermal surface activity (e.g., sinter deposits and/or areas of steaming ground) is not observed. High CO2 mixing ratios were observed at the top of some fault strands (474

Copyright 2014, University of Auckland. Readers who download papers from this site should honour the copyright of the original authors, and may not copy or distribute the work further without the permission of the original publisher.

You have opened 0 records today from 216.73.216.152 (216.73.216.152).