Accuracy of Flow Monitoring Using TFT Micromod in SNGPF
- Key words
- accuracy, mass flow, metered, Micromod, Tracer Flow
- Location
- Southern Negros, Philippines
- Conference
- Asian Geothermal Symposium
- Year
- 2013
- Language
- English
Full text
1 MB, opens in a new tab
Abstract
Well mass flow data is important in the management of a geothermal filed. In Southern Negros Geothermal Production Field, TFT Micromod System is the technology widely used to determine mass flows in production wells. It is important that data derived from this technology must be accurate and reliable. Evaluation of the accuracy of this system when compared to online metered steam flow measurement showed that TFT Micromod results are within 5% deviation.
Copyright 2013, Asian Geothermal Symposium. Readers who download papers from this site should honour the copyright of the original authors, and may not copy or distribute the work further without the permission of the original publisher.