Abstract

Experimental study on Vapor Compression Heat Pump (VCHP) is carried out with the aims to upgrade shallow depth and low temperature geothermal water to a higher temperature (at least 20 °C higher) suitable for use in drying facilities for agricultural products. Five working fluids, R-22 (Chlorodifluoromethane), R-290 (Propane), R-134a (1,1,1,2- Tetrafluoroethane), R-717 (Ammonia) and R-123 (2,2-Dichloro-1,1,1-trifluoroethane) have been considered and simulated. The simulation results showed that R-123 was the most suitable refrigerant for the heat pump due to its lower high-side pressure and highest coefficient of performance (COP). The R-123 VCHP is capable to upgrade supplied water temperature of 40OC from the water-cooled condensers to hot water temperature of 80 °C. Single stage VCHP using R123 as working fluid is equipped to a drying room of 3.3 x 4.8 x3.2 meters in dimension, at Huai Mak Liam hot spring area in Chiang Rai Province. The shallow depth well of 85 meters supplies water temperatures in and out of the heat pump as 50 °C and 47 °C, respectively. The coefficient of performance of drying room is 2.68 with the room temperature increases from 25 °C to 70 °C within 3 hours.

Copyright 2013, Asian Geothermal Symposium. Readers who download papers from this site should honour the copyright of the original authors, and may not copy or distribute the work further without the permission of the original publisher.

You have opened 0 records today from 216.73.217.5 (216.73.217.5).
Viewed 21 September 2026, 11:30 pm.