Conference Papers Database New search

Kawerau TOPP1 Geothermal Fluid Supply

Greg McPherson, Kevin Koorey

Key words
Kawerau, Binary power plant, Two phase fluid supply
Location
Kawerau, New Zealand
Conference
New Zealand Geothermal Workshop
Year
2013
Language
English

Full text

592 KB, opens in a new tab

Abstract

The TOPP1 binary cycle power plant located on Kaweraugeothermal field is supplied with steam and geothermalseparated water from a number of separation plants. Theseparation plants are located some distance from each otherand operate at different pressures. The design of thedelivery system for the separated water to the power planthad to overcome the pressure differences. This wasachieved by controlling the plant inlet pressure below thelowest separator pressure and allowing for some flashing ofthe water before entering the plant.

Copyright 2013, University of Auckland. Readers who download papers from this site should honour the copyright of the original authors, and may not copy or distribute the work further without the permission of the original publisher.