Geothermal Steam Measurement with Orifice Plates: Cerro Prieto Update
- Key words
- The Americas; Steam measurement, orifice plate
- Location
- Cerro Prieto, Mexico
- Conference
- Geothermal Resources Council Transactions
- Year
- 2006
- Session
- Steam measurement; orifice plate
- Language
- English
Abstract
Last year CFE analyzed the problems related flow measurement. To certify the steam flow rates in the delivery points in the Cerro Prieto Geothermal field, where this steam is received by the operation team and used in for electricity generation. In 2005 one of these points was inspected and the possible problems evaluated in order to meet the ISO 5167 standard requirements and obtain a possible certification. At this time, the code was studied and the pressure taps and the internal roughness of the pipe were the most significant problems to be solved as well as the circularity of the pipe, because the code ask for a tolerance +/- 3% and ASME accepts +/- 5%. With this experience, CFE decided to sign a contract with the Centro Nacional de MetrologĂa (CENAM) the official institution responsible to deliver a certificate and verify a 36 inch pipe transporting steam for Cerro Prieto IV. The physical measurements and the results of this experience are presented.
Copyright 2006, Geothermal Resources Council. Readers who download papers from this site should honour the copyright of the original authors, and may not copy or distribute the work further without the permission of the original publisher.