Conference Papers Database New search

The Estimation of Reservoir Pore Volume from Tracer Data

Sabin, A.E., Unruh, J.R., Walker, J.D., Monastero, F.W., Lovekin, J., Robertson-Tait, A., Ross, H., Sorensen, M., Leong, R., Holte, C.T., Amos, C., Blackwell, D

Key words
Resource assessment, Geothermal energy, military lands
Location
Nellis Air Force Base, Nevada; Las Vegas, Nevada; El Centro, California; Imperial Valley
Conference
Stanford Geothermal Workshop
Year
2004
Session
FIELD STUDIES
Language
English

Full text

4468KB, opens in a new tab

Abstract

Innovative Technical Solutions, Inc. (ITSI) evaluated
geothermal potential on selected military bases in the
U.S. for the Department of Defense. Assessment
activities included literature reviews, interviews with
local specialists, geothermal field investigations at 3
installations, and development of conceptual
geothermal occurrence models. Occurrence models
integrate geothermal system characteristics with local
structural/tectonic characteristics to identify potential
geothermal targets. Spatial analyses of selected
coverages using GIS were also performed for the
ranges at Nellis AFB in order to identify possible
geothermal targets.

NAF El Centro has ìhighî utility-grade geothermal
potential and at least four other installations
investigated warrant additional investigation.
Twenty-one western U.S. installations have direct-use
geothermal potential, with bases in Oregon,
Nevada and California having the greatest potential.

Copyright 2004, Stanford Geothermal Program. Readers who download papers from this site should honour the copyright of the original authors, and may not copy or distribute the work further without the permission of the original publisher.

Attend the next Stanford Geothermal Workshop. Workshop details
You have opened 0 records today from 216.73.216.139 (216.73.216.139).