Conference Papers Database New search

Parametric Sensitivity Study of Operating and Design Variables in Wellbore Heat Exchangers

Gopi Nalla, G. Michael Shook, Gregory L. Mines, K. Kit Bloomfield

Key words
WELLBORE HEAT EXCHANGERS, sensitivity analysis, engineered geothermal system
Conference
Stanford Geothermal Workshop
Year
2004
Session
MODELING
Language
English

Full text

313KB, opens in a new tab

Abstract

A numerical study was conducted to evaluate the
potential for using a Wellbore Heat Exchanger
model for power generation. Variables studied
included operational parameters such as
circulation rates, wellbore geometries and
working fluid properties, and regional properties
including basal heat flux and formation rock
type. Energy extraction is strongly affected by
fluid residence time and heat transfer contact
area, and by formation thermal properties. Water
appears to be the most appropriate working fluid.
Aside from minimal tubing insulation, tubing
properties are second order effects.
On the basis of the sensitivity study, a Best Case
model was simulated, and results compared
against existing, low-temperature power
generation plants. Even assuming ideal work
conversion to electric power, a wellbore heat
exchange model cannot generate 200 kW at the
onset of pseudo-steady state. Using realistic
conversion efficiency, the method is unlikely
able to generate 50 kW.

Copyright 2004, Stanford Geothermal Program. Readers who download papers from this site should honour the copyright of the original authors, and may not copy or distribute the work further without the permission of the original publisher.

Attend the next Stanford Geothermal Workshop. Workshop details
You have opened 0 records today from 216.73.216.199 (216.73.216.199).
Viewed 22 September 2026, 6:50 am.