Geothermal Two-Phase Pressure Loss in a Bend
- Conference
- New Zealand Geothermal Workshop
- Year
- 2000
- Session
- Fluid Production, Separation & Transmission
- Language
- English
Full text
2267KB, opens in a new tab
Abstract
When a two-phase fluid flows through a bend, its flow pattern is disturbed. The ChisholmÃs (1980) pressure drop correlation for bends was tested using geothermal two-phase flow data. ChisholmÃs (1980) correlation under-predicts the measured pressure drops by 50%. Other correlations: Chisholm C-type (1967), Sookprasong (1980), Kuhn & Morris (1997) and Paliwoda (1992) all use a twophase multiplier method. A new correlation is proposed using frictional and momentum components for the total pressure drop through a long radius (LR) elbow. The new correlation predicts the measured data to within 5%.
Copyright 2000, University of Auckland. Readers who download papers from this site should honour the copyright of the original authors, and may not copy or distribute the work further without the permission of the original publisher.