Factors Affecting the Capital Cost of Binary Power Plants
- Key words
- Economics; Power Generation; USA; Binary Systems; Working Fluid; Financing; Operating Costs; Efficiency; Power Plant Design; Turbine Design; Cooling Towers; Isobutane; Pilot Projects; Capital Cost; Ammonia Plant; Hydrocarbon; Comparative Evaluations
- Conference
- Geothermal Resources Council Transactions
- Year
- 1991
- Session
- Economics; Binary cycle power generation; Working fluids; Po
- Language
- English
Abstract
The capital cost for a representative binary plant using hydrocarbon working fluid and rejecting heat with a cooling tower is $1775/KW of net power output. The cost of a comparable ammonia plant is $1450/KW. If a spray pong is used instead of a cooling tower the cost is reduced to $1250/KW. These costs do not include the wells, geofluid pumps, and piping which will add an additional $300/KW.