Conference Papers Database New search

Corrosion and Scaling in the Well H-16 of the Los Humeros Geothermal Field

Gutierrez Negrin, Luis C. A.; Viggiano Guerra, Julio C.

Key words
Production; Brine Technology; Exploration; Drilling; Mexico; Veracruz; Puebla; Los Humeros; Case Histories; Corrosion; Scaling; Silica; Sulfides; HC1; Geology; Caldera; Alteration; Noncondensable Gas; Lithology; Chemistry; Geochemistry; Liners; Oxides; Hy
Location
Los Humeros, Mexico
Conference
Geothermal Resources Council Transactions
Year
1990
Session
Corrosion; Scaling; Brine chemistry; Tubulars
Language
English

Full text

Open the paper

Opens in a new tab

Abstract

The liner pipes of well H-16 from Los Humeros geothermal field were strongly corroded and incrusted by silica and iron sulphides. The corrosion process seems to be happened to an average rate of 0.752 mm/year and HCI from deep zones of the geothermal reservoir seems to be the cause. The scaling of the liner pipe was induced by mixing of the deep fluids and another fluids produced from a shallower zone (around 1400-1450 m depth). Future wells located at the same area of the field (the Central Collapse), should to avoid the mixing of fluids from both zones in order to prevent the scaling and to reduce the corrosion rates.

Copyright 1990, Geothermal Resources Council. Readers who download papers from this site should honour the copyright of the original authors, and may not copy or distribute the work further without the permission of the original publisher.