Conference Papers Database New search

Optimum Operational Pressure for a 55 MW Turbine Utilized in a Wet Steam Field

Mendez-Lopez, G.; Quintero-Nunez, M.

Key words
Power Generation; Mexico; Sonoma; Cerro Prieto; Efficiency; Operation Designs; Scaling; Turbine Design; Corrosion; Enthalpy; Entropy; Dryness
Location
Cerro Prieto, Mexico
Conference
Geothermal Resources Council Transactions
Year
1989
Session
Turbines; Equipment design; Power plant design and operation
Language
English

Full text

Open the paper

Opens in a new tab

Abstract

The objective of this work is to calculate the optimum pressures for the technical operation of a 55 MW double cylinder turbine in a tandem configuration using mass and energy balance equations, accompanied by a technical economic study. The maximum dryness at the turbine outlet should be kept at 85% and the power generation maintained constant. The values of the various calculated steam pressures were 10, 9, 8 and 7 bar and 3.5, 3.2, 2.5 and 2.0 bar, for the high and low steam pressures respectively, while at the turbine outlet the pressure was kept constant at 0.075 bar. The most important results obtained showed that, the re were two pressures with the best performance: 9 bar and 3.2 of high and low steam pressure, respectively and 0.075 bar at the turbine outlet. Other relevant alternatives were also found.

Copyright 1989, Geothermal Resources Council. Readers who download papers from this site should honour the copyright of the original authors, and may not copy or distribute the work further without the permission of the original publisher.

Attend the 2026 Geothermal Rising Conference. Meeting details
You have opened 0 records today from 216.73.216.174 (216.73.216.174).
Viewed 21 September 2026, 11:05 am.