As part of reporting and sidetracking EE-2 geothermal well, a number of cementing operations were successfully carried out. These included; a) plugging back of EE-2 below the proposed side track site, b) cement behind casing at 10220-24 ft, c) cement behind casing at 9800-04 ft, d) a whipstock plug, and e) the cementing through perforations, of the 9-5/8 in. casing from 6500 ft to the surface. Specific data on each of these operations is given, and the results discussed.