Wellhead Power Plants and Operating Experience at Wendel Hot Springs

Nichols, Kenneth E.

Key words
Power Generation; Engineering; USA; California; Binary Cycle; Rankine Cycle; Working Fluid; Availability Factor; Operating Design; Turbines; Condenser; Generator; Controls; Pumps; Module; Susanville; Wineagle Power Plant; Pumps; Barber-Nichols Engineering
Location
Wendel Hot Springs, California
Conference
Geothermal Resources Council Transactions
Year
1986
Session
Power plant design and operation; Working fluids
Language
English

Full text

Open the paper

Opens in a new tab

Abstract

Modular wellhead power plants, based on the organic Rankine cycle, have proven reliability with high utilization of the available resource. The power cycle is adaptable to water or steam temperatures of 180°F to 350°F. The power plant working fluid is a halogenated hydrocarbon refrigerant that is selected to provide high overall performance. The working fluid is nontoxic and nonflammable. These features reduce system cost and provide safer operation. Each power plant consists of one module which contains all of the heat excgangers, power turbine, alternator and controls. The power plant can generate from 300 kW to over 100 kW. The larger size plants utilize additional heat rejection modules. Multiple plants can be located at the wellhead, producing several megawatts. These plants can be on line in approximately six months from project initiation. Operating experience at the Wineagle Power Project, located at Wendel Hot Springs, has demonstrated a plant availability greater than 95% since commencing commercial operation in September of 1985. Module performance features and operating experience are discussed in the paper.

Copyright 1986, Geothermal Resources Council. Readers who download papers from this site should honour the copyright of the original authors, and may not copy or distribute the work further without the permission of the original publisher.

Attend the 2026 Geothermal Rising Conference. Meeting details
You have opened 0 records today from 216.73.216.199 (216.73.216.199).
Viewed 22 September 2026, 5:54 am.