Conference Papers Database New search

Examination of Insulation Wear Modes in Geothermal Logging Cables

Grant, Tracy

Key words
Well Tests; Logs; Wireline; Temperature Logs
Conference
Geothermal Resources Council Transactions
Year
1985
Session
Well logging; Equipment design; Durability testing; Logging
Language
English

Full text

Open the paper

Opens in a new tab

Abstract

The wear mode of the Tetrafluoroethylene (TFE) insulation used on an electrical logging cable is described. The cable examined in this study was used repeatedly in various harsh geothermal environments. Considering the amount of abuse the cable was subjected to , the TFE performed very well. Grooves were formed on the outside of the insulation as a result of the fluid pressure and the loading from the inner layer of metal armor. Also, indentations on the inside of the insulation were caused by the insulation molding to the conductor strands. If this mode of wear were to continue, the conductors would eventually protrude from the insulation and short out against each other or the cable armor.

Copyright 1985, Geothermal Resources Council. Readers who download papers from this site should honour the copyright of the original authors, and may not copy or distribute the work further without the permission of the original publisher.