Cost Effective Air Pollution Control for Geothermal Powerplants
- Key words
- Power Generation; Research Agencies; USA; California; Geysers; H2S Abatement; LBL; Chemistry; Scrubbers; Condensers
- Location
- The Geysers, California
- Conference
- Geothermal Resources Council Transactions
- Year
- 1985
- Session
- Air quality; Hydrogen sulfide; Scrubbers; Condensers; Efflue
- Language
- English
Abstract
Air pollution control technology developed and demonstrated at the Geysers by the Pacific Gas and Electric Company includes two different, but equally effective methods to reduce the emissions of hydrogen sulfide from geothermal power plants. These technologies may be used in other geothermal areas as well. Cost saving modifications and adaption's needed to apply these technologies in to the geothermal areas with different steam composition are described. Cost estimates are presented for some typical cases. If a surface condenser gives poor H2S partitioning with ammonia rich steam, neutralizing the ammonia with SO2 is a cost effective alternative to secondary abatement with hydrogen peroxide. Nickel is cost effective alternative to FeHEDTA when an oxidation catalyst is added to the cooling water of a power plant equipped with a contact condenser.
Copyright 1985, Geothermal Resources Council. Readers who download papers from this site should honour the copyright of the original authors, and may not copy or distribute the work further without the permission of the original publisher.