Conference Papers Database New search

Status Summary of the HGP-A Generator Facility: 1983

Thomas, Donald M.

Key words
Power Generation; USA; Hawaii; Puna; Flash; Design
Location
Puna, Hawaii
Conference
Geothermal Resources Council Transactions
Year
1983
Session
Brine chemistry; Power plant design and operation; Turbines;
Language
English

Full text

Open the paper

Opens in a new tab

Abstract

The HGP-A Generator Facility has been in nearly continuous operation for approximately 15 months. During this period well flow and power plant output have been maintained at 49,9000 kg/hr and 2.9 Mwe respectively. The quality and chemical composition of the steam from the well has been quite stable, whereas the salinity of the brines produced has increased steadily. The operational performance of the steam supply system has remained within specifications whereas maintenance difficulties with trip and control value hydraulics have been experienced. The hydrogen sulfide abatement systems for normal and standby conditions have proven to be quite effective, however, the operating costs of both systems have been found to be extremely high. Silica deposition rates within the brine control and disposal system have gradually increased since beginning operations and are presently considered to be the major impediments to continued operation of the facility. A major overhaul of the HGP-A Generator Facility is currently planned to take place in the near future.

Copyright 1983, Geothermal Resources Council. Readers who download papers from this site should honour the copyright of the original authors, and may not copy or distribute the work further without the permission of the original publisher.

Attend the 2026 Geothermal Rising Conference. Meeting details
You have opened 0 records today from 216.73.216.139 (216.73.216.139).
Viewed 29 September 2026, 5:00 pm.