Hydrogen Sulfide Oxidation Test Program

Soo-Hoo, Randall; Hipkin, Howard; Cochrane, Frank

Key words
Power Generation; USA; California; pH; Temperature; Cooling Towers; Condensers; Operating Designs; Flow Systems; Well Pad; Flow Rate
Location
The Geysers, California
Conference
Geothermal Resources Council Transactions
Year
1982
Session
Hydrogen sulfide; Environmental aspects; Air quality; Vapor
Language
English

Full text

Open the paper

Opens in a new tab

Abstract

This paper summarizes the results of a project carried out for the California Department of Water Resource (DWR) by Bechtel at the Geysers area to field test the oxidation of hydrogen sulfide in geothermal steam condensate using hydrogrren peroxide. The objective was to find the oxidant-catalyst combination that will remove sufficient sulfide to allow power plant operation without violating air pollution H2S emission standards. Batch screening test, bench scale flow tests, and pilot plant for tests were made on condensed steam from one of the wells than will supply the DWR Bottle Rock power plant. The effects of treatment ratio, pH, catalyst, residence time, and temperature were tested. Based on the test results, a conceptual design was prepared for a recommended abatement system for the power plant.

Copyright 1982, Geothermal Resources Council. Readers who download papers from this site should honour the copyright of the original authors, and may not copy or distribute the work further without the permission of the original publisher.

Attend the 2026 Geothermal Rising Conference. Meeting details
You have opened 0 records today from 216.73.216.139 (216.73.216.139).
Viewed 28 September 2026, 4:08 pm.