Conference Papers Database New search

A Bench Scale Test for Hydrogen Sulfide Oxidation

Ivester, J.; Attiga, S.; Castillo, M.; Goldman, E.

Key words
Brine Technology; Power Generation; Sulfides; Steam; Condensate; pH; Operating Designs; Conductivity; Thermodynamics; Pressure; Cooling Tower; MWe
Location
The Geysers, California
Conference
Geothermal Resources Council Transactions
Year
1982
Session
Hydrogen sulfide; Environmental aspects; Air quality; Vapor
Language
English

Full text

Open the paper

Opens in a new tab

Abstract

The oxidation of hydrogen sulfide in geothermal steam condensate by hydrogen peroxide was tested in a specially designed, continuous flow bench scale treatment system. The effectiveness of the treatment way monitored using a silver/sulfide specific ion electrode in a technique developed specially for this study. The effects of pH, treatment ratio, and catalyst on the oxidation reaction were studied. The results of the study were used to operate a pilot plant treatment system to determine optimal peroxide treatment conditions. The bench scale studies identified iron as the catalyst of choice and indicated that the pilot plant testing could concentrate on the pH expected in the full scale plat, pH 8. The bench scale studies further indicated that pilot plant testing would not need to include hydrogen peroxide to sulfide treatment ratios of greater than 4:1 and that lower ratios might be adequate.

Copyright 1982, Geothermal Resources Council. Readers who download papers from this site should honour the copyright of the original authors, and may not copy or distribute the work further without the permission of the original publisher.

Attend the 2026 Geothermal Rising Conference. Meeting details
You have opened 0 records today from 216.73.217.80 (216.73.217.80).
Viewed 22 September 2026, 8:45 am.