Conference Papers Database New search

Downhole Cement Test in a Very Hot Hole

Pettitt, Roland A.; Cocks, George G.; Dreesen, Donald S.; Sims, James R.; Nicholson, Robert W.; Boevers, Billy G.

Key words
Hot Dry Rock; USA; Temperature; Fractures; Casing; Silica; Joints; Injection Well; Borehole; Cementing; Test Results; Downhole Cement Test
Location
Fenton Hill, New Mexico; Valles Caldera, New Mexico
Conference
Geothermal Resources Council Transactions
Year
1982
Session
HDR/EGS; Cementing; Well completion
Language
English

Full text

Open the paper

Opens in a new tab

Abstract

Completion of the commercial sized Hot Dry Rock Geothermal Energy Project requires that hydraulic fractures be created between two inclined wellbores at a depth of about 4 km (15,000ft). Isolation of a section of the open wellbore is necessary for pressurization to achieve the fracture connections. A cemented in liner/PBR assembly is one of the methods used for zone isolation near the bottom of the injection well. A downhole, pumped cement test was first conducted at a wellbore temperature of 275°C (525°F) to determine if a suitable slurry could be designed, pumped, and later recovered to assure the success of the cemented in liner operation.

Copyright 1982, Geothermal Resources Council. Readers who download papers from this site should honour the copyright of the original authors, and may not copy or distribute the work further without the permission of the original publisher.