Conference Papers Database New search

Field Test Results of Improved Geothermal Roller Cone Bits

Maish, Alexander B.

Key words
Drilling; Drill Bit; Field Test; USA; California; Geysers; Roller Cove; Hard Rocks; High Temperature; Bit Life; Gage Wear; Materials; Hearing Life; Unsealed Bearings; Reamings; Graywacki; Airdrilling; US DOE; Sandia; Terra Tek; Reed Tool Company
Location
The Geysers, California
Conference
Geothermal Resources Council Transactions
Year
1979
Session
Drilling; Drill bits; Air drilling
Language
English

Full text

Open the paper

Opens in a new tab

Abstract

The third generation geothermal tricone bit under development by Sandia Laboratories and Terra Tek was field tested at the Geysers geothermal area in California. Data taken during the tests were analyzed to determine the performance of the research bit as compared with the performance of a preferred tricone bit currently in use. An analysis of the bit gage wear, which is a major factor in bit life in this hard rock area, determined that the research bit had a 30 percent increase in gage life compared with the conventional roller cone bit. Improvements in bearing and insert life were also measured. The optimal drilling run duration was determined for this formation as a function of reaming time and drilling time.

Copyright 1979, Geothermal Resources Council. Readers who download papers from this site should honour the copyright of the original authors, and may not copy or distribute the work further without the permission of the original publisher.

Attend the 2026 Geothermal Rising Conference. Meeting details