Conference Papers Database New search

Broadlands Optimisation

Grant, Malcolm A.

Key words
Reservoir Engineering; Power Plant; New Zealand; North Island; Broad Lands; Well Tests; Plant Design; Simulation; Field Capacity; Power Cycle; Flash Steam; Ohaaki; Mass Flow; Production History; Reinjection; DSIR
Location
Broadlands, New Zealand; Ohaaki, New Zealand; Taupo Volcanic Zone
Conference
Geothermal Resources Council Transactions
Year
1979
Session
Power plant design and operation; Two phase flow; Flash stea
Language
English

Full text

Open the paper

Opens in a new tab

Abstract

A lumped parameter model of Broadlands geothermal field was used to study possible power station configurations. For two stage flash, a broad optimum was found in the inlet pressure on the turbine, from 6 to 10 bar with a value at the low end of range, 6.2 bar being recommended. A three stage flash was also considered, and the best choice was the use of temporary HP topping, sets. These HP sets would be sustained for one third of the stations lifetime.

Copyright 1979, Geothermal Resources Council. Readers who download papers from this site should honour the copyright of the original authors, and may not copy or distribute the work further without the permission of the original publisher.