This paper details an investigation of two phase, water/steam, pressure drop on a 10 cm diameter test loop sited on the Wairakei (NZ) steam field. Measurements of straight pipe and duct component losses are presented using a liquid velocity derived from a void fraction correlation. A horizontal flow straight pipe correlation is presented based on data from a 20 cm diameter pipeline and component pressure losses are demonstrated to be of such a magnitude as to be significant in a two phase pipeline reticulation system.
Copyright 1979, Geothermal Resources Council. Readers who download papers from this site should honour the copyright of the original authors, and may not copy or distribute the work further without the permission of the original publisher.