The Size Effect for District Space Heating in Boise, Idaho

Kunze, J. F.; Donovan, L. E.; Griffith, J. L.

Key words
Direct use; Economics; Piping; Utilization factor; Boise; Idaho; USA
Location
Boise, Idaho
Conference
Geothermal Resources Council Transactions
Year
1977
Session
Direct use; District heating/cooling; Space heating/cooling;
Language
English

Full text

Open the paper

Opens in a new tab

Abstract

Heating portions of the city of Boise with geothermal water seems attractive, because the 170°F resource was confirmed with drilling in the summer of 1976 to be within 1-1/2 miles of the downtown business district. However, the capital cost of installing pipelines to transport the hot water under the city streets is so large a capital investment that nearly full capacity utilization is necessary to recover the investment. Furthermore, enhancing the annual utilization factor on the pipelines to the maximum is necessary in the moderate temperate climate. A doubling of the utilization factor is possible by using fossil fuel to peak the system on the few cold days. Design of the geothermal system so fossil must peak for about 6% of the heating needs during the season appears to give the optimum return on investment.