Average Heat Load of District Heating System of Balcova

Macit Toksoy, Cihan Canakci and Umran Serpen

Key words
District heating system, peak load, average heat load
Location
Balcova, Turkey
Conference
World Geothermal Congress
Year
2005
Session
23. District Heating and Agriculture
Language
English
Paper number
2319

Full text

59KB, opens in a new tab

Abstract

In this study, to estimate the average heat load of buildings within the Balcova district heating system, the data of 40 buildings whose heating system were installed after sound projects were taken into account. The average peak load per unit area of the buildings that are situated within Balcova district heating system is calculated on the basis of design heat loads of 40 buildings with heating system projects and the change of heat loads with respect to several parameters is investigated. The weighted average load per unit area is found 54.9 kCal/m2h for a design temperature differential of 22oC from the data pertinent to 40 buildings. The weighted average load per unit volume is calculated 18.3 kCal/m3h.

Copyright 2005, International Geothermal Association. Readers who download papers from this site should honour the copyright of the original authors, and may not copy or distribute the work further without the permission of the original publisher.