Conference Papers Database New search

Application of Modified Isochronal Test to Determine Output Curve of Wells at Kamojang Geothermal Field-West Java

Muhammad Achyar Karim, Aidil Hasibuan, Firman, Wawan Darmawan, Ali Ashat

Key words
production test, back pressure, modified isochronal
Location
Kawah Kamojang, Indonesia; Java
Conference
World Geothermal Congress
Year
2005
Session
11. Reservoir Engineering
Language
English
Paper number
1192

Full text

416KB, opens in a new tab

Abstract

Attempts were made at Kamojang Geothermal field, West Java, to apply Modified Isochronal Test to determine output curve from production test of KMJ-73 and KMJ-74 wells. In the past, wells at the Kamojang Geothermal field were tested using Back Pressure Method. The results of the test were satisfactory. However, the test was time consuming. Three months were spent testing a single well. The disadvantages of this test are high cost and delayed revenue gained from the wells.
The result of the modified isochronal test has a good agreement with those obtained from back pressure test. The main advantage of modified isochronal test is duration of the test. Completion of modified isochronal test takes only 10 days. However, before it becomes an alternative method for testing dry steam wells, validation of this method is needed by applying it to other wells.

Copyright 2005, International Geothermal Association. Readers who download papers from this site should honour the copyright of the original authors, and may not copy or distribute the work further without the permission of the original publisher.

Attend the 2029 World Geothermal Congress. Congress details
You have opened 0 records today from 216.73.217.54 (216.73.217.54).
Viewed 21 September 2026, 12:20 am.